The glass thickness and air space in the double glaze of units vary depending on the parameter of window and wind load. In order to choose the ideal glass thickness according to glass dimensions and their areas, the table prepared assuming an average 150kg/m2 wind load has been presented below.
 

Technical Details

 

Glass Thickness

Air Space

Max. area and dimension

Weight kg/m²

Production tolerance

 
 

 

 

 

Dimension mm

Area

Thickness mm

Width height mm

 

 
 

3+3

6

1500

1.00

15.5

 +0.4

0./+2

difference between corners
4 mm

 

9

1600

1.20

 +1.4

 

12

1600

1.40

 

 

4+4

6

1600

1.50

20

 +0.6

0./+2

 

9

1800

2.00

 +1.6

 

12

2000

2.60

 

 

5+5

6

2100

3.00

25

 +0.6

0./+3

 

9

2300

3.80

 +1.6

 

12

2500

4.20

 

 

6+6

6

2500

5.00

29

 +0.8

0,5/+2

 

9

2700

5.80

 +1.8

 

12

3000

6.90